C0001 |
LCT connection failed |
|
C0202 |
Tray 1 feeder up/down abnormality • The paper feed tray 1 upper limit sensor is not blocked even after the lapse of a given period of time after the lifting motion has been started. |
1 Check the M8 connector for proper connection and correct as necessary. 2 Check the connector of M8 for proper drive coupling and correct as necessary. 3 PS8 I/O check, sensor check. 4 M8 operation check. 5 Change M8. 6 Change PRCB. |
C0204 |
Tray 2 feeder up/down abnormality • The paper feed tray 2 upper limit sensor is not blocked even after the lapse of a given period of time after the lifting motion has been started. |
1 Check the M9 connector for proper connection and correct as necessary. 2 Check the connector of M9 for proper drive coupling and correct as necessary. 3 PS15 I/O check, sensor check. 4 M9 operation check. 5 Change M9. 6 Change PRCB. |
C0206 |
Tray 3 feeder up/down abnormality |
|
C0208 |
Tray 4 feeder up/down abnormality |
|
C0209 |
LCT elevator motor malfunction |
|
C0210 |
LCT ascent motion failure |
|
C0211 |
Manual feed up/down abnormality • The manual lift-up position sensor is not unblocked even when the transport motor has turned for a given number of pulses after the sequence to move the paper lifting plate from the standby position to the feed position was started. • The manual lift-up position sensor is not blocked even when the transport motor has turned for a given number of pulses after the sequence to move the paper lifting plate from the feed position to the standby position was started. |
1 Check the M1 connector for proper connection and correct as necessary. 2 Check the connector of M1 for proper drive coupling and correct as necessary. 3 PS17 I/O check, sensor check. 4 SL1 operation check. 5 M1 operation check. 6 Change SL1. 7 Change M1. 8 Change PRCB. |
C0212 |
LCT ejection failure |
|
C0213 |
LCT shift gate malfunction |
|
C0214 |
LCT shifting failure |
|
C0215 |
LCT shift motor malfunction |
|
C0301 |
Suction fan motor’s failure to turn • The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary. |
1 Check the FM8 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM8 operation check. 4 Change FM8. 5 Change PRCB. |
C0351 |
Paper cooling fan motor’s failure to turn • The fan lock signal remains HIGH for a predetermined continuous period of time while the motor remains stationary. |
1 Check the FM7 connector for proper connection and correct as necessary. 2 Check the fan for possible overload and correct as necessary. 3 FM7 operation check. 4 Change FM7. 5 Change PRCB. |
C1004 |
FNS communication error |
|